|
|
DSCR H15: SPECIAL INSTRUCTIONS FOR COMPRESSED GAS REQUIREMENTS
Deprecated: Function mysql_numrows() is deprecated in /home/simplyauto/www/regs/supplycenters/dscr/clause.php on line 182
Section: H
DPACS Code: H15
BSM Code: H45F30
Clause Number: 52.245-9G01
Type: LOCAL
Clause last updated: 1996-01
Status: Deleted
Replaced by: this row
|
Date of text: 1996-01 (current version)
H15 52.245-9G01 SPECIAL INSTRUCTIONS FOR DSCR (JAN 1996)
AND COMPRESSED GAS
H45F30
CONTRACTS, PURCHASE ORDERS OR DELIVERY ORDERS
(a) Acknowledgment of Receipt: Within ten days after receipt
of cylinders, Contractor will submit copies of DD 1348-1, annotated
as to date, quantity received, and quantity rejected, to the
Administrative Contracting Office (ACO), indicated in the
"Administered By" block on page 1 of the contract, and to the
Defense Supply Center Richmond, ATTN: DSCR-JJB (GFP Monitor),
Richmond, VA 23297-5862. A copy of DD 1348-1 must accompany
cylinders when returned to the depot by the Contractor.
(b) If the quantity of cylinders to be filled is less than that
prescribed by the contract/order (considering any allowable variation
in quantity) due to failure of the Government to provide the proper
number of cylinders to the Contractor, or due to rejection of
cylinders by the Contractor, the ACO will modify the contract/order
and reduce the quantity of cylinders to be filled accordingly.
Rejected cylinders will not be replaced.
(c) Repair/Reconditioning - Government Furnished Cylinders:
(1) Except as noted below, cylinders shall be repaired
and/or reconditioned under the terms of this contract or at the
request of the Quality Assurance Representative (QAR) except that:
(i) The authorized dollar limitation stated herein
shall not be exceeded without prior approval of the ACO, and
(ii) The Contractor shall, when the authorized dollar
limitation has been expended, contact the ACO for availability of
additional funds and/or disposition instructions, prior to further repair
/reconditioning or return of cylinders.
(2) Cylinders received from DLA Supply Depots shall not be
commingled with cylinders from any other activity.
(3) In accordance with MIL-STD-1411, repair and/or
reconditioning of cylinders as set forth above shall be itemized on
DD Form 250, Material Inspection and Receiving Report. A copy of
the DD Form 250 shall be furnished to the Defense Supply Center
Richmond, ATTN: DSCR-JJB (GFP Monitor), Richmond, VA 23297-5862.
Cylinders rejected as unsuitable for repair will also be itemized
citing the reason/rationale for rejection.
(d) Filling and Testing: Cylinders received that vary in
characteristics from that indicated in the item description shall be
reported immediately to the ACO. Upon identification of such cylinders
to a proper NSN they will be filled to their rated capacity and
reidentified to the designated National Stock Number as advised by
the procuring activity. (10% over fill is not authorized for DLA
activities except as noted below.) Rejected cylinders shall not be
replaced. The contract will be considered complete for the quantity
of cylinders filled.
(e) Delivery orders: In the event of a conflict between these
special instructions and the basic contract, the latter will govern.
Warning: require(/home/simplyauto/www/includes/site_footer.php): failed to open stream: Permission denied in /home/simplyauto/www/regs/supplycenters/dscr/clause.php on line 369
Fatal error: require(): Failed opening required '../../../includes/site_footer.php' (include_path='.:/usr/local/lib/php') in /home/simplyauto/www/regs/supplycenters/dscr/clause.php on line 369
|